SECTOR II

Motor Voltage
Daily Operations
Remotes Storage
Lengths (m)
SECTOR II Traffic Barrier: Efficient Installations, Superior Performance
The SECTOR II Traffic Barrier is a high-volume solution designed specifically for commercial and industrial applications. Its installer-focused features, durable construction, and advanced engineering make it the ideal choice for traffic control in high-demand environments. From quick installations to seamless integration with existing systems, the SECTOR II streamlines the process for professionals while delivering a reliable and robust barrier solution.
Applications: Industrial/Commercial/Residential (for example housing estates and gated communities).
Housing Options for Every Environment
The SECTOR II Traffic Barrier’s housing is available in a range of materials to suit different environmental and climatic conditions:
- Inland Applications: Zinc-passivated mild steel for superior durability and protection against general wear and tear.
- Coastal Plains: Grade 430 stainless steel with an epoxy coating to resist corrosion in salty and humid conditions.
- Marine Environments: Grade 316 brushed stainless steel offers maximum corrosion resistance for the most demanding marine applications.
Additionally, the housing can be customised in a range of colours to match the aesthetics of the installation site or branding requirements.
What Makes the SECTOR II a Dream for Installers?
Enhanced Boom Pole and Visibility for Superior Performance
Boom Pole Options
The SECTOR II Traffic Barrier is available with two boom pole options to suit different installation needs:
- Standard Round Pole: A dependable solution for general applications.
- Improved Rectangular Boom Pole: Offers enhanced strength and durability, making it ideal for high-volume, demanding environments. This option also includes a polymer bumper, which provides added protection by reducing the impact in the unlikely event of accidental contact, ensuring enhanced safety and peace of mind. An integrated LED strip delivers clear illumination, improving safety and visibility even in low-light conditions.
Streamlined Installation Process
- User-Friendly Control Interfaces: Conveniently located at the top of the enclosure, the SECTOR II’s control interfaces simplify configuration and setup.
- Optimised Wire Routing: Thoughtfully designed wire pathways minimise setup time and reduce onsite disruption.
- Seamless System Integration: Easily integrates with security solutions like CLAWS barrier spikes and TRAPEX fencing, creating a comprehensive traffic control solution.
Rugged and Reliable Construction
- Heavy-Duty Design: Built for the rigors of daily operation, with a weather-resistant steel and aluminium enclosure that withstands heavy use and harsh environments.
- Stronger Boom Pole: Features a rectangular boom pole for enhanced strength and reliability, ensuring durability in high-volume traffic scenarios.
Intuitive LCD Interface
- Graphic Setup Wizard: Simplifies commissioning and configuration, allowing installers to quickly set up the barrier.
- Diagnostic Tools: Built-in diagnostic capabilities ensure quick troubleshooting and optimal system performance.
Energy Efficiency and Sustainability
- Low power consumption reduces operational costs while supporting eco-friendly installations.
- Compatible with solar panel options, allowing installers to offer renewable energy solutions to clients for even greater efficiency.
Energy Efficiency
Energy efficiency is a key consideration in the SECTOR II’s design. With low power consumption, this barrier reduces operational costs while promoting sustainability. Installers can also offer clients solar panel options, enabling the SECTOR II to run on renewable energy, which adds to its eco-friendly credentials and further lowers energy expenses.
Why Install the SECTOR II?
As an installer, you need solutions that are efficient, reliable, and easy to configure. The SECTOR II delivers on all fronts, with advanced tools and robust design features that make installations faster, smarter, and more professional. Upgrade your clients’ traffic control systems with confidence—choose the SECTOR II Traffic Barrier.
Added Extras for Traffic Management and Security
Enhance the functionality of your SECTOR II Traffic Barrier with optional add-ons:
- TRAPEX Fence: Provides an added layer of security to prevent unauthorised pedestrian access.
- FLUX Vehicle Detectors: Ensures precise vehicle detection for seamless operation.
- MIDI Traffic Light: Directs and controls vehicle flow efficiently, improving traffic management at access points.
- CLAWS Barrier Spikes: Boosts security with a physical deterrent for unauthorised entry or exit.
- Breakaway Coupler: Offers an additional safety measure by disconnecting the boom pole during accidental impact to prevent damage to the motor.
- Jack-Knife Mechanism: Designed for installations where ceiling height restrictions require a longer boom pole to fold upward, ensuring seamless operation in low-clearance areas.
- SECTOR II Rectangular Boom Pole Brochure
- SECTOR II Rectangular Boom Pole Installation Manual
- SECTOR II Rectangular Boom Pole Shroud Installation Manual
- SECTOR II Rectangular Boom Pole Jack-Knife Installation Manual
- SECTOR II Rectangular Boom Pole Jack-Knife LED Installation Manual
- SECTOR II Rectangular Boom Joiner Installation Manual
- SECTOR II Rectangular Boom Pole LED Installation Manual
- SECTOR II Rectangular Boom Pole Coupling Installation Manual
- SECTOR II Rectangular Boom Pole Break-Away Coupling Installation Manual

Become a Trusted Professional
With specialised, in depth training in servicing, maintaining, installing and repairs of all SMΔRT Centurion Systems Motors.

TECHNICAL DATA | SECTOR II 3m | SECTOR II 4.5m | SECTOR II 6m | |
---|---|---|---|---|
Input Voltage1 | 220 - 240V AC +\- 10% @ 50Hz | 220 - 240V AC +\- 10% @ 50Hz | 220 - 240V AC +\- 10% @ 50Hz | |
Motor Voltage | 12V DC | 12V DC | 12V DC | |
Motor Power Supply2 | Battery-driven | Battery-driven | Battery-driven | |
Boom Pole Length3 | 3.0m | 4.5m | 6.0m | |
Boom Pole Raise Time | 1.2 sec | 3 sec | 3 sec | |
Daily Operations - Max | 3000 | 3000 | 3000 | |
Duty Cycle - Mains Present | 80% | 80% | 80% | |
Housing Specification | Inland - Zinc-passivated mild steel Coastal plains - Grade 430 Stainless Steel with Epoxy Coating Marine - Grade 316 Brushed Stainless Steel | Inland - Zinc-passivated mild steel Coastal plains - Grade 430 Stainless Steel with Epoxy Coating Marine - Grade 316 Brushed Stainless Steel | Inland - Zinc-passivated mild steel Coastal plains - Grade 430 Stainless Steel with Epoxy Coating Marine - Grade 316 Brushed Stainless Steel | |
Operations in standby with 7Ah battery | ||||
Onboard Receiver Specification | CENTURION code-hopping, multichannel, 433MHz, with 500 remote control button storage capacity | CENTURION code-hopping, multichannel, 433MHz, with 500 remote control button storage capacity | CENTURION code-hopping, multichannel, 433MHz, with 500 remote control button storage capacity | |
Half day5 | 3000 | 2900 | 2900 | |
Full day5 | 3000 | 2300 | 2300 | |
Collision sensing | Electronic | Electronic | Electronic | |
Operating temperature range | -15°C to 55°C ambient | -15°C to 55°C ambient | -15°C to 55°C ambient | |
Receiver code storage capacity | 500 Transmitter buttons | 500 Transmitter buttons | 500 Transmitter buttons | |
Receiver frequency | 433.92 MHz | 433.92 MHz | 433.92 MHz |
1. Can operate off a solar supply, consult Centurion Systems (Pty) Ltd for assistance.
2. Battery capacity can be increased for longer standby times (Battery capacity </=33Ah unless charger is upgraded).
3. Boom-pole raise and lower-times are both individually configurable to suit individual installation requirements.
4. Based on 25°C ambient temperature and unit not in direct sunlight.
5. Based on an output torque of less than 50% of rated torque.
6. Based on basic operator excluding closing-loop detector.
7. Limited by daily usage.
8. The model designation of the barrier is an indication of the maximum length of pole for the specific spring.
In other words, SECTOR II 3m = maximum 3m pole; SECTOR II 4.5m = maximum 4.5m pole, etc.
In other words, if you wish to fit a 4.5m pole, a SECTOR II 4.5m/6m with corresponding spring must be used.
9. Refer to a battery data sheet for battery operating temperatures.
10. For particularly hot areas, the Operator will remain within its operating temperature if the product is installed in a shaded
environment.