Visual Aid

Tuning Freq. from 5 (μH)

Lightning Protection (KA)

FLUX Inductive Loop Detectors: Advanced, Quick-to-Install Vehicle Detection

FLUX is a high-performance, single-channel inductive loop detector range designed for accurate and reliable vehicle detection in access control applications.

With options for both standalone and 11-pin models, FLUX detectors are engineered for ease of installation and commissioning, allowing installers to provide efficient and hassle-free solutions to their clients.

Applications: Compatible with traffic barriers, swing gate motors, and sliding gate motors

What Sets the CENTURION Loop Detectors Apart?

Simple Installation and Commissioning

FLUX detectors are designed for straightforward installation, enabling installers to set up and configure access control quickly and efficiently.

Audible and Visual Diagnostics

Equipped with both sound and light indicators, FLUX makes diagnostics during installation intuitive, reducing setup time.

Removable Terminals for Quick Maintenance

The FLUX range includes removable terminals, streamlining maintenance tasks and enabling faster troubleshooting when needed.

Convenient Boot-Loader Interface

FLUX includes a boot-loader interface that simplifies firmware upgrades, keeping the detector up-to-date with minimal effort.

Dedicated Reset Button

A dedicated reset button allows installers to perform quick resets, facilitating smooth maintenance processes.

/

Compact Housing Design

FLUX’s compact design is crafted to optimise space, with features that enhance ease of installation and provide straightforward access to monitoring diagnostics.

Become a Trusted Professional

With specialised, in depth training in servicing, maintaining, installing and repairs of all SMΔRT Centurion Systems Motors.

FLUX SA DESCRIPTION
Operating Voltage 10 - 40V DC, or 7 - 28V AC
Standby Current 50mA
Output Relay Rating 1A @ 125V AC
Detection Time 4ms @ 100kHz loop frequency | 10ms @ 40kHz loop frequency
Visual LED Indicators Showing Power; Loop Fault; Loop detection level (five LED's); Detect
Audible Indicators Buzzer with indication of loop detection level and loop fault
Weight 92g
Detector Tuning Range 15 - 1500μH
Electronics Protection Insolation transformer with 10kA lightning protection
Dimensions 105mm (length) X 60mm (width) X 26mm (height)
FLUX 11 12V DC MODEL 230V AC MODEL
Supply Voltage 10 - 40V DC, or 7 - 28V AC 220V - 240V AC +/- 10% 50Hz
Standby Current 50mA <10mA
Output Relay Rating 1A @ 125V AC 1A @ 125V AC
Detection Time 4ms @100kHz loop frequency | 10ms @ 40kHz loop frequency 4ms @100kHz loop frequency | 10ms @ 40kHz loop frequency
Visual LED Indicators LED indicators showing: Power; Loop Fault; Loop detection level (five LEDs); Detect LED indicators showing: Power; Loop Fault; Loop detection level (five LEDs); Detect
Audible Indicators Buzzer with indication of loop detection level and loop fault Buzzer with indication of loop detection level and loop fault
Weight 92g 92g
Detector Tuning Range 15 - 1500μH 15 - 1500μH
Electronics Protection Isolation transformer with 10kA lightning protection Isolation transformer with 10kA lightning protection
Dimensions 96mm (length) X 42mm (width) X 80mm (height) 96mm (length) X 42mm (width) X 80mm (height)
IP Rating IP 50 IP 50